Jump to content
 

trevora

Members
  • Posts

    109
  • Joined

  • Last visited

Everything posted by trevora

  1. when i started out we got 4 gallons to the pound and change so what should I feel
  2. It needs the grid for reference so no grid no reference Also it would feed power into a "dead" grid and could kill anyone working on it
  3. could you use this https://forum.mrhmag.com/post/sma20-low-cost-17-channel-dcc-decoders-ver-6-01-with-soundtriggered-soundstepperdual-motorled-and-12201920 arduino plus relay after the dcc interface £5.00 worth of bits
  4. Just set up a new windows 11 pc and it,s fine here also no adds
  5. look at these https://www.youchoos.co.uk/Index-Shop.php?L1=Wire
  6. Yes you can not just bung a barrel of the stuff in a pickup and run it out to the middle of nowhere to keep the plant moving, you may have to run the plant to a good road to refuel not whats done on small jobs now
  7. My wife had a family member with a glass eye and drove hgvs in the 70,s
  8. Cornwall's Eden Project set to begin £17m hot rocks drilling programme Huge drill arrives ready to bore three miles into the Earth and pump down water so it can be superheated underground
  9. you may need to change to R8241 as these do not have dc suppresion bits in
  10. Please can anyone talk me step by step in activating TPM other half and i both have msi amd mother boards if i plus module in pc will not boot tried changing settings and got mine to boot but doing TPM.cmd says cant find module Trevora
  11. Sorry to hear pepole are not glad of the help you offer and end up treating you like that please keep helping those that treat you right sod the others they do not deserved help anyway I have been glad of help from here & if that had not worked maybe your help could have been asked of next
  12. Newcastle-under-Lyme or upon tyne
  13. Great thanks all working got so close but too close to see what i was missing Once again your life savers
  14. This is what i tried same as above but with extra maybe not what was required? DCC_Fully_Working_with_5_addresses.ino
  15. Yes i have 8 tracks on the transfer table (transverser() and two leading to it & the sketch hashome (200) pluas three (201-202-203) i tried adding 204 which worked but then 203 did not so what needs adding /changing to get five addresses instead of four please
  16. Please I have this working driving my transfer table But i have 8 tracks fed by two tracks each end (in line) when i tried to add 204 it worked but i lost 203 the file is /was by Rigid Collosion but he seems not around these days DCC_Fully_Working_with_Parking_Sensor.ino
  17. OK so i have loaded Alex Shepards sketch and my transverser moves when i put 200 -209 and thrown/straight with my dcc handset (he had it for turntable so small moves) I set the transverser using the serail monitor and have home in the centre each track is about 9600 steps apart This is where i need help putting that in his sketch
  18. https://www.dcctrainautomation.co.uk/zimo-mx622-miniature-decoder-14-x-9-x-25mm-08-amp-wires-only.html not cheapest but good
  19. I have got it all together and can run table back & fore manually So now need help putting a sketch together and tweaking As needed to line up with tracks etc List of hardware Arduino Model Railway DCC Interface (www.dccinterface.com) Arduino mega 57hs56 Nema 23 stepper motor TB67S driver with 109AFTG chip 1604 ball screw (4mm per rev) IR transmitters’ & IR sensor’s for limit stops and home 2mtr x 0.4mtr transfer table with 8 tracks at 48mm crs Two tracks leading in one end Two in line the other So train could run straight though Have run dcc interface with dcc monitor Have run stepper demo Have run Ir sensors So main thing is to incorporate all together Setting up nine stops if my tracks are right Or 16 if they need tweaking of spacing’s Trevora
×
×
  • Create New...